CISPR 16-1-2-2017 PDF
Name in English:
St CISPR 16-1-2-2017
Name in Russian:
Ст CISPR 16-1-2-2017
Original standard CISPR 16-1-2-2017 in PDF full version. Additional info + preview on request
Full title and description
CISPR 16-1-2: Specification for radio disturbance and immunity measuring apparatus and methods — Part 1-2: Radio disturbance and immunity measuring apparatus — Coupling devices for conducted disturbance measurements. The consolidated publication is edition 2.0 (2014) with Amendment 1 (2017), and it specifies characteristics and performance requirements for coupling devices and ancillary apparatus used for conducted disturbance measurements.
Abstract
This standard sets out the requirements for coupling and decoupling networks, artificial mains networks (AMNs), current and voltage probes and other coupling devices used when measuring conducted radio disturbance voltages and currents in the frequency range 9 kHz to 1 GHz. It is a basic horizontal EMC publication intended to harmonize the performance and interaction of measuring apparatus and ancillary equipment used in type and compliance testing.
General information
- Status: Published — consolidated edition 2.0 (2014) with Amendment 1 (2017) available.
- Publication date: Edition 2.0 published 21 March 2014; Amendment 1 published 7 November 2017 (consolidated/CSV available).
- Publisher: International Electrotechnical Commission (IEC) — CISPR technical committee.
- ICS / categories: 33.100.10; 33.100.20.
- Edition / version: Edition 2.0 (2014) with Amendment 1 (2017) — consolidated as CISPR 16-1-2:2014+AMD1:2017.
- Number of pages: Base publication 183 pages (2014 edition); Amendment 1 is 22 pages (2017). Consolidated formats are available.
Scope
Covers the design characteristics, performance and required parameters of coupling devices and ancillary apparatus used for conducted disturbance measurements (including artificial mains networks, coupling/decoupling networks, probes and coupling units for current injection) for the frequency range 9 kHz to 1 GHz. The standard defines standardized RF load impedances, measurement configurations and requirements to ensure repeatable, comparable measurements across test laboratories and product categories.
Key topics and requirements
- Definitions and classification of coupling devices and ancillary apparatus (AMNs, V‑AMN, Δ‑AN, CDNE, AAN).
- Impedance and transfer impedance requirements for artificial mains networks and probes across specified frequency bands.
- Construction, placement and grounding/ground‑loop avoidance measures for AMNs and related equipment in test configurations.
- Performance tolerances, RF isolation recommendations for measuring instruments and ancillary equipment, and guidance for powering/connection to avoid measurement artefacts.
- Requirements for coupling units used for conducted immunity/current injection tests and standardized measurement interfaces.
Typical use and users
Used by EMC test laboratories, test-house engineers, calibration laboratories, manufacturers of measuring receivers and ancillary EMC test equipment, product standards committees that reference EMC test methods, and regulatory/market‑surveillance bodies responsible for ensuring compliance with conducted disturbance limits.
Related standards
CISPR 16-1-2 is part of the CISPR 16 series. Closely related documents include the CISPR 16-2 series (methods of measurement), CISPR 16-3 (information on radio disturbance) and the CISPR 16-4 series (uncertainty, statistics and modelling of limits). Product-specific CISPR standards (for example CISPR product publications) reference CISPR 16-1-2 for coupling device requirements.
Keywords
EMC; CISPR 16-1-2; coupling devices; artificial mains network; AMN; conducted disturbance; conducted emissions; measurement apparatus; V‑AMN; Δ‑AN; CDNE; EMC test methods.
FAQ
Q: What is this standard?
A: An IEC/CISPR horizontal EMC standard that specifies characteristics and performance requirements for coupling devices and ancillary apparatus used in conducted disturbance measurements.
Q: What does it cover?
A: It covers artificial mains networks, coupling/decoupling networks, probes, coupling units for current injection, impedance specifications and test‑set configuration guidance for conducted disturbance measurements in the 9 kHz–1 GHz range.
Q: Who typically uses it?
A: EMC test labs, instrument and AN/AMN manufacturers, standards writers, product test engineers and conformity assessment bodies use it to design equipment and perform standardized conducted emissions and immunity tests.
Q: Is it current or superseded?
A: The authoritative edition is edition 2.0 (published 21 March 2014) with Amendment 1 published 7 November 2017; consolidated versions (2014+AMD1:2017) are available. The IEC entry shows a stability date into 2026 for the consolidated edition.
Q: Is it part of a series?
A: Yes — it is Part 1-2 of the CISPR 16 family (CISPR 16-1-x, 16-2-x, 16-3, 16-4 etc.), which together cover measurement apparatus, methods, information and uncertainty/statistics for radio disturbance and immunity measurements.
Q: What are the key keywords?
A: Artificial mains network (AMN), coupling/decoupling network (CDN), V‑AMN, Δ‑AN, coupling units, conducted disturbance, conducted emissions, EMC measurement apparatus, CISPR 16.