Full title and description

Specification for radio disturbance and immunity measuring apparatus and methods — Part 1-1: Radio disturbance and immunity measuring apparatus — Measuring apparatus (CISPR 16-1-1:2019). The document specifies characteristics and performance requirements for equipment used to measure radio disturbance (EMI) and related measuring apparatus operating in the 9 kHz to 18 GHz range, and includes requirements for specialized equipment for discontinuous disturbance measurements.

Abstract

This standard (Edition 5.0, 2019) is a basic CISPR/IEC EMC publication that defines performance, accuracy and testing/validation requirements for EMI receivers, spectrum analyzers and discontinuous disturbance analysers (e.g., click analyzers). It covers detector response types (quasi‑peak, peak, average, RMS‑average), key receiver characteristics, validation and calibration procedures (including Annex J), and guidance on use of spectrum analyzers and APD/measurement functions where applicable.

General information

  • Status: Published / Current (fifth edition, in force; stability date shown as 2026).
  • Publication date: 22 May 2019.
  • Publisher: International Electrotechnical Commission (IEC) — CISPR (International Special Committee on Radio Interference).
  • ICS / categories: 33.100.10 (Electromagnetic compatibility — EMC).
  • Edition / version: Edition 5.0 (2019).
  • Number of pages: 195 pages.

Key bibliographic details above are taken from the IEC product record for CISPR 16-1-1:2019.

Scope

Covers specification of measuring apparatus used for the measurement of radio disturbance voltages, currents and fields in the frequency range 9 kHz to 18 GHz. The scope includes fundamental performance parameters for measuring receivers and spectrum analyzers, requirements for detectors and discontinuous disturbance analysers, and normative requirements for verification, calibration and validation of measuring equipment. It is intended as a basic EMC publication to be used by product committees to determine applicability for specific product tests.

Key topics and requirements

  • Frequency range of applicability: 9 kHz to 18 GHz.
  • Performance characteristics for measuring receivers and spectrum analyzers (input impedance, selectivity, bandwidth, tuning tolerance, rejection ratios, overload behaviour).
  • Detector types and response requirements: quasi‑peak, peak, average and RMS‑average detectors and their pulse/continuous response characteristics.
  • Discontinuous disturbance analysers (click analyzers): fundamental characteristics and validation/test methods for transient/disturbance capture.
  • Calibration, verification and validation procedures for measuring apparatus (Annex J and other normative guidance), including test methods for pulse generators and nanosecond pulse measurement techniques.
  • Guidance on use of spectrum analyzers for compliance measurements and references to related parts of CISPR 16 for ancillary equipment and test sites.

These topics and specific requirements are defined and expanded in the clauses and annexes of CISPR 16-1-1:2019.

Typical use and users

Used by EMC test laboratories, product test engineers, instrument manufacturers, conformity assessment bodies, and IEC/CISPR product committees. Typical uses include instrument design/validation, laboratory accreditation and setting measurement practices for product emission testing and compliance assessment.

Related standards

CISPR 16-1-1 is part of the CISPR 16 family. Closely related documents include other CISPR 16 parts (for example CISPR 16-1-2, 16-1-3, 16-1-4, 16-1-5) and the Part 2 measurement methods (e.g., CISPR 16-2-1, 16-2-3) and the CISPR 16-4 series on uncertainties/statistics. Use CISPR 16-2-x documents for measurement methods and CISPR 16-1-x for ancillary apparatus and test-site/antenna requirements.

Keywords

EMC; EMI receivers; measuring receiver; spectrum analyzer; quasi‑peak detector; peak detector; RMS‑average; discontinuous disturbance analyser; click analyzer; calibration; validation; 9 kHz–18 GHz; CISPR 16.

FAQ

Q: What is this standard?

A: CISPR 16-1-1:2019 is the fifth edition of the CISPR specification that defines performance and measurement requirements for radio‑disturbance and immunity measuring apparatus (measuring receivers and related instruments).

Q: What does it cover?

A: It covers technical characteristics and required performance of measuring receivers and spectrum analyzers for EMI measurements across 9 kHz to 18 GHz, detector response definitions, requirements for discontinuous disturbance analysers, and calibration/validation methods (including several normative annexes).

Q: Who typically uses it?

A: EMC laboratories, instrument manufacturers, test engineers, conformity assessment bodies and standards/product committees use this standard to design, validate and apply measurement apparatus and to ensure consistent measurement practice for emissions testing.

Q: Is it current or superseded?

A: CISPR 16-1-1:2019 (Ed. 5.0) supersedes the 2015 edition and is shown by IEC as the current fifth edition (publication date 22 May 2019) with a stability date indicated as 2026; no later edition of Part 1-1 was published at the time of this record. Users should check the IEC webstore or national bodies for any amendments or revisions after 2019.

Q: Is it part of a series?

A: Yes — it is Part 1-1 of the CISPR 16 series (CISPR 16-1-x, CISPR 16-2-x, CISPR 16-3, CISPR 16-4, etc.), which together specify measuring apparatus, ancillary equipment, measurement methods and uncertainty/statistics guidance for EMC testing.

Q: What are the key keywords?

A: EMC, EMI receiver, measuring receiver, spectrum analyzer, quasi‑peak, RMS‑average, peak detector, discontinuous disturbance analyser, calibration, validation, 9 kHz–18 GHz, CISPR 16.