Description in English:

Original standard IEC 61290-4-1-2016 in PDF full version. Additional info + preview on request

Description in Russian:
Оригинальный стандарт IEC 61290-4-1-2016 в PDF полная версия. Дополнительная инфо + превью по запросу
Document status:
Active

Format:
Electronic (PDF)

Delivery time (for English version):
1 business day

Delivery time (for Russian version):
365 business days

SKU:
stiec04984

Choose Document Language:
€35

Full title and description

Optical amplifiers - Test methods - Part 4-1: Gain transient parameters - Two-wavelength method. This international standard specifies a two-wavelength test method for measuring gain transient behaviour of optical amplifiers using active fibres (optical fibre amplifiers, OFAs) including erbium-doped fibre amplifiers (EDFAs) and other rare-earth-doped devices, and for optically amplified elementary sub-systems.

Abstract

IEC 61290-4-1:2016 (second edition) provides background on transient phenomena in optical fibre amplifiers and defines a standardized, repeatable two-wavelength measurement method to determine transient gain metrics that occur when channels are added or removed in wavelength-division multiplexed systems. The standard covers definitions, required measurement apparatus, test specimen and procedure, calculation methods and reporting of results, and includes informative annexes on transient behaviour and slew-rate effects.

General information

  • Status: International Standard — Current (2nd edition, replaces the 2011 edition)
  • Publication date: 26 September 2016
  • Publisher: International Electrotechnical Commission (IEC), TC 86/SC 86C
  • ICS / categories: 33.180.30 (Fibre optics / Optical amplifiers)
  • Edition / version: Edition 2.0 (Second edition, 2016)
  • Number of pages: 39

Scope

This part of IEC 61290 applies to optical amplifiers (OAs) that use active fibres (optical fibre amplifiers, OFAs) containing rare-earth dopants (including EDFAs) and to optically amplified elementary sub-systems. Its objective is to provide the technical background for OFA transients and to describe a standard two-wavelength test method for accurate and reliable measurement of gain transient parameters that occur when wavelength channels are added or removed in a multichannel system.

Key topics and requirements

  • Definition and explanation of gain transient phenomena in OFAs and related terminology.
  • Standardized two-wavelength measurement procedure for transient events caused by channel add/drop.
  • Measured parameters: transient gain overshoot, transient net gain overshoot, transient gain undershoot, transient net gain undershoot, gain offset (steady-state change), and transient gain response time constant (settling time).
  • Required measurement apparatus, test specimen configuration, stimulus waveforms and timing, and data acquisition recommendations to ensure repeatability and accuracy.
  • Calculation methods for deriving the transient metrics from acquired traces and required test reporting formats.
  • Informative annexes providing background on transient mechanisms in optical amplifiers and the effect of slew rate on transient responses.
  • Normative references and consistency of definitions with other parts of the IEC 61290 series.

Typical use and users

Used by optical amplifier manufacturers (OFA/EDFA vendors) for product characterization and datasheet verification; by test laboratories and certification bodies performing conformity and interoperability testing; by network equipment vendors and service providers for system design and qualification; and by R&D teams studying amplifier dynamics and WDM system behavior.

Related standards

Part of the IEC 61290 series of basic specifications and test methods for optical amplifiers. Closely related documents include: IEC 61290-4-2 (broadband source method for gain transients), IEC 61290-1-1 and IEC 61290-1-2 (power and gain parameter test methods), IEC 61290-5 series (reflectance parameters), IEC 61290-10 series (multichannel parameters), and IEC 61291 series (performance specifications for optical amplifiers).

Keywords

optical amplifiers, optical fibre amplifiers (OFA), EDFA, gain transient, two-wavelength method, transient overshoot, transient undershoot, gain offset, settling time, test method, WDM, fibre optics

FAQ

Q: What is this standard?

A: IEC 61290-4-1:2016 is an international test-method standard that defines a two-wavelength procedure to measure gain transient parameters of optical fibre amplifiers and optically amplified sub-systems.

Q: What does it cover?

A: It covers the background, apparatus, test specimen configuration, detailed test procedure, calculations and reporting for measuring transient gain overshoot/undershoot, gain offset and settling time when channels are added or removed.

Q: Who typically uses it?

A: OFA and EDFA manufacturers, independent test labs, telecom equipment vendors, service providers, and R&D teams working on amplifier dynamics and WDM system performance.

Q: Is it current or superseded?

A: The 2016 edition (second edition) supersedes the 2011 edition. It is the current edition published in 2016 and remains the applicable IEC text for this part of the 61290 series.

Q: Is it part of a series?

A: Yes — it is one part of the IEC 61290 family of basic specifications and test methods for optical amplifiers; other parts address different measurement techniques and parameters (power/gain, reflectance, multichannel tests, etc.).

Q: What are the key keywords?