IEC 61992-6-2020 PDF
Name in English:
St IEC 61992-6-2020
Name in Russian:
Ст IEC 61992-6-2020
Original standard IEC 61992-6-2020 in PDF full version. Additional info + preview on request
Full title and description
St IEC 61992-6-2020 — Railway applications — Fixed installations — DC switchgear — Part 6: DC switchgear assemblies. This entry typically refers to the consolidated edition incorporating Amendment 2 published in 2020, providing requirements and guidance for the design, construction and verification of DC switchgear assemblies used in fixed railway installations.
Abstract
IEC 61992-6 specifies requirements for DC switchgear assemblies for use in fixed installations of traction (railway) systems. The consolidated document reflects the original 2006 publication together with subsequent amendments up to 2020, and covers functional, constructional and testing aspects needed to ensure safe, reliable DC switchgear assemblies in traction applications.
General information
- Status: Active / Consolidated edition (base publication 2006 with amendments including AMD2:2020).
- Publication date: 26 May 2020 (consolidated amendment publication date).
- Publisher: International Electrotechnical Commission (IEC).
- ICS / categories: 45.060.01 (Railway rolling stock in general).
- Edition / version: Edition 1.0 (consolidated with amendments: IEC 61992-6:2006/AMD2:2020).
- Number of pages: 12 (consolidated/amendment document length as published).
Scope
This part of IEC 61992 applies to DC switchgear assemblies intended for fixed railway installations with nominal DC voltages (the IEC 61992 series addresses fixed installations supplying guided public transport). It sets out requirements for assembly construction, ratings, protective devices, coordination, documentation and testing to ensure safe operation within DC traction environments.
Key topics and requirements
- Definition and classification of DC switchgear assemblies for fixed railway installations.
- Electrical ratings, insulation and clearances appropriate to DC traction systems.
- Requirements for protective devices, switching components and interlocks.
- Verification and type/production testing procedures for assemblies.
- Marking, documentation and information to be supplied with assemblies (ratings, wiring diagrams, maintenance instructions).
- Requirements for mechanical construction, ventilation and accessibility for maintenance.
Typical use and users
Primary users include manufacturers of DC switchgear assemblies, railway system integrators, specification and procurement engineers, testing and certification laboratories, and maintenance departments of rail infrastructure operators who specify or verify compliance of fixed DC switchgear used in traction power substations and associated installations.
Related standards
IEC 61992 is a multipart series; related parts include Part 1 (General), Part 2 (DC circuit breakers), Part 3 (Indoor disconnectors/switch-disconnectors/earthing switches), Part 4 (Outdoor disconnectors/switch-disconnectors/earthing switches), Part 5 (Surge arresters/limiters) and Part 7 (measurement/control/protection devices), which together define the DC switchgear and controlgear requirements for traction systems.
Keywords
DC switchgear assemblies; railway fixed installations; traction power; IEC 61992; DC circuit protection; switchgear testing; railway electrical equipment.
FAQ
Q: What is this standard?
A: IEC 61992-6 (consolidated with amendments to 2020) is the part of the IEC 61992 series that specifies requirements for DC switchgear assemblies used in fixed railway installations.
Q: What does it cover?
A: It covers classification, electrical and mechanical requirements, protective device coordination, testing and documentation for DC switchgear assemblies intended for traction (railway) fixed installations.
Q: Who typically uses it?
A: Switchgear manufacturers, railway engineers and system integrators, procurement/specification teams, test laboratories and maintenance organisations within rail infrastructure providers.
Q: Is it current or superseded?
A: The consolidated form incorporating Amendment 2 (2020) is an active publication; users should confirm any later corrigenda or amendments from IEC for the very latest status before procurement or certification activities.
Q: Is it part of a series?
A: Yes — IEC 61992 is a multipart series covering DC switchgear and controlgear for fixed railway installations; Part 6 focuses specifically on DC switchgear assemblies while other parts address circuit-breakers, disconnectors, surge arresters and measurement/protection devices.
Q: What are the key keywords?
A: DC switchgear, railway fixed installations, traction power, switchgear assemblies, IEC 61992, protection coordination, type testing.