IEC 62895-2017 PDF

St IEC 62895-2017

Name in English:
St IEC 62895-2017

Name in Russian:
Ст IEC 62895-2017

Description in English:

Original standard IEC 62895-2017 in PDF full version. Additional info + preview on request

Description in Russian:
Оригинальный стандарт IEC 62895-2017 в PDF полная версия. Дополнительная инфо + превью по запросу
Document status:
Active

Format:
Electronic (PDF)

Delivery time (for English version):
1 business day

Delivery time (for Russian version):
365 business days

SKU:
stiec07694

Choose Document Language:
€35

Full title and description

St IEC 62895-2017 — High voltage direct current (HVDC) power transmission — Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications — Test methods and requirements. This International Electrotechnical Commission (IEC) standard specifies test methods and technical requirements for single-core HVDC power cables with extruded insulation and their associated accessories (joints, terminations, outdoor accessories) intended for fixed land installations up to and including 320 kV.

Abstract

IEC 62895:2017 defines the test procedures and performance requirements used to verify the electrical, mechanical and environmental behaviour of HVDC extruded-insulation cable systems and accessories for land applications up to 320 kV. It covers material definitions, sample preparation, type and routine tests, and special test conditions for joints and terminations used in transmission systems operating in direct current (DC) environments.

General information

  • Status: Published (International Standard; nationally adopted in some markets).
  • Publication date: 11 May 2017.
  • Publisher: International Electrotechnical Commission (IEC), Technical Committee TC 20 — Electric cables.
  • ICS / categories: 29.060.20 (Cables).
  • Edition / version: Edition 1.0 (2017).
  • Number of pages: 136 pages (official IEC publication).

Scope

IEC 62895:2017 applies to transmission power cable systems comprising single-core cables with extruded insulation and their accessories for fixed land installations with rated voltages up to and including 320 kV. "Extruded insulation" includes thermoplastic and crosslinked polymeric insulations (for example PE, XLPE, EPR) whether filled or unfilled. The standard addresses normal installation and operation conditions for cables, outdoor terminations (including for gas-insulated systems), joints and asymmetric joints. It excludes special cable types (for example submarine cables) for which test modifications or special test conditions may be required.

Key topics and requirements

  • Definitions and material characterization for extruded insulation and relevant conductor and sheath materials.
  • Type tests and routine tests for cable cores, accessories, joints and terminations under HVDC stress conditions.
  • Electrical tests including DC withstand, partial discharge measurements and impulse tests where applicable.
  • Mechanical and environmental tests: aging, thermal cycling, bending, tensile, and water/impurity resistance relevant to long-term HVDC operation.
  • Requirements and tests for accessories (joints, terminations) ensuring compatibility with cable system performance.
  • Sample preparation, testing arrangements and acceptance criteria for manufacturers and test laboratories.
  • Normative references to related IEC test-method standards (for example high-voltage measurement methods and non-metallic materials tests).

Typical use and users

Used by cable manufacturers, accessory (joint and termination) makers, testing laboratories, transmission system planners, consulting engineers and procurement/specification teams involved in HVDC land transmission projects. The standard is referenced in type approval, factory testing, contract specifications and performance verification for extruded-insulation HVDC cable systems up to 320 kV.

Related standards

IEC 62895:2017 is part of the family of IEC cable test standards and is commonly used alongside other IEC documents such as IEC 60840 (extruded-insulation power cables and accessories for up to 150 kV), IEC 62067 (extruded-insulation power cables for higher voltages), the IEC 60060 series (high-voltage test techniques), and the IEC 60811 series (tests for non-metallic materials). National adoptions exist (for example BS IEC 62895:2017) and regional versions may be published under EN/ISO adoption processes.

Keywords

HVDC, high-voltage direct current, extruded insulation, XLPE, polyethylene, power cables, cable accessories, joints, terminations, test methods, 320 kV, IEC TC 20.

FAQ

Q: What is this standard?

A: IEC 62895:2017 is an IEC International Standard that specifies test methods and requirements for single-core extruded-insulation HVDC power cables and their accessories for land applications up to 320 kV.

Q: What does it cover?

A: It covers definitions, sample preparation, type and routine tests, electrical and mechanical test methods, and acceptance criteria for cables, joints and terminations intended for HVDC transmission systems up to and including 320 kV.

Q: Who typically uses it?

A: Cable manufacturers, accessory suppliers (joints/terminations), independent test laboratories, system designers, utilities, procurement/specification engineers and consultants working on HVDC land transmission projects.

Q: Is it current or superseded?

A: IEC 62895:2017 (edition 1.0) was published on 11 May 2017. The IEC publication record indicates this edition is the 2017 edition; the IEC webstore lists a stability horizon into 2026. As with any standard, users should verify whether a later edition or amendment has been published after 11 May 2017 before finalizing specifications (this summary reflects the standard status as of 25 February 2026).

Q: Is it part of a series?

A: Yes. It belongs to the family of IEC standards for power cables with extruded insulation and is related to other voltage-range-specific standards (for example IEC 60840 and IEC 62067) and to IEC test-method series such as IEC 60060 and IEC 60811.

Q: What are the key keywords?

A: HVDC, extruded insulation, XLPE, power transmission cables, joints, terminations, test methods, 320 kV.